WebJul 19, 2024 · Set Parameters 128 and 212 to values of 0. Push [RESET] to stop each alarm. Go into DEBUG mode. Push [ZERO RETURN]. Push [A]. Push [SINGLE]. Note: Ignore the ZERO RETURN MARGIN TOO SMALL alarm. Type … WebAlarm: 194 B ZERO RET MARGIN TOO SMALL. Haas Alarm Description: This alarm will occur if the home/limit switches move or are misadjusted. This alarm indicates that the zero return position may not be consistent from one zero return to the next. The encoder Z channel signal must occur between 1/8 and 7/8 revolution of where the home switch …
Easy Axis Homing - HAAS Automation UK
WebJul 19, 2024 · Set Parameters 128 and 212 to values of 0. Push [RESET] to stop each alarm. Go into DEBUG mode. Push [ZERO RETURN]. Push [A]. Push [SINGLE]. Note: Ignore the ZERO RETURN MARGIN TOO SMALL alarm. Type GRID A on the Raw Data Screen. Make sure that Parameter 128 has a value [1]. If Parameter 128 does not have a … WebThe way to do this is using the Home G28 button which can be found on the Zero Return Mode line. By pressing the Home G28 button with the doors shut this will command the machine to send all axes to their home location, on a Haas mill this will take the Z axis home first then the X and Y axes after the Z axis has finished and on a Haas Lathe it will Take … mid lincs football league 2021/22
Haas Alarm: 168 A ZERO RET MARGIN TOO SMALL - Helman CNC
WebHaas Alarm: 167 Z ZERO RET MARGIN TOO SMALL – This alarm will occur if the home/limit switches move or are misadjusted. It indicates that the zero return position may not be consistent from one zero return to the next. The encoder Z channel signal must occur between 1/8 and 7/8 revolution of where the home switch releases. WebHaas Alarm: 165 X ZERO RET MARGIN TOO SMALL – This alarm will occur if the home/limit switches move or are misadjusted. It indicates that the zero return position may not be consistent from one zero return to the next. The encoder Z channel signal must occur between 1/8 and 7/8 revolution of where the home switch releases. WebApr 13, 2009 · Have been having alarm 166 (Y return margin too small) error upon zeroing all axis on startup. I have replaced the mechanical Y axis limit switch to no avail. I checked the switch connections for tightness as well as the servo-motor connectors. I have had this problem before and cleaned the limit switch and it solved the problem but not … midlight electric